Rev. bras. cir. plást ; 28(4): 699-701, july-sept. 2013.
Artigo em Inglês | LILACS | ID: lil-779151

RESUMO

The rupture of silicone implants for injury due gunshot is rare with only two cases reported, and only one implant was done with gel high-cohesive. A male patient, 25 years transsexual with breast implants silicone, was the victim of gunshot wound. The bullet penetrated the posterior chest and get off at the anterior-medial chest which transfixed the prosthesis. During digital exploration of the wound, still at the surgical emergency, it was found the rupture of the implant, taking place however only the simple suture of the skin. It was performed ultrasonography, computed tomography and magnetic resonance imaging exam, the results showed no perforation of the prosthesis and silicone leakage. Faced with the assertion ofthe general surgeon that had perforation of the implant, it was indicated the immediate removal of the prosthesis, but the patient refused to be operated by evading the hospital. After two months he had hyperemia and the silicone liked out of the wound. Then he looked for a particular service to exchange the prosthesis. We can conclude that despite of the high specificity of current imaging studies, the artificial high-density silicone may be presented without modification to examinations and their removal is the treatment of choice...


A ruptura do implante de silicone devido à ferimento por arma de fogo é um evento raro, com apenas dois casos descritos na literatura, sendo que somente em um deles o implante era feito com gel de alta coesão. Paciente masculino, 25 anos, transexual, com prótese mamária de silicone, vítima de ferimento por arma de fogo, sendo que o projétil entrou na região dorsal e saiu através da região antero-mediai direita do tórax, transfixando a prótese. Durante a exploração digital do ferimento da mama, ainda no centro cirúrgico da emergência, foi constatada a ruptura do implante, realizando-se, no entanto, somente a sutura simples da pele. Realizadas ultrassonografia, tomografia computadorizada e ressonância magnética; nenhum exame demonstrou perfuração da prótese e extravasamento do silicone. Diante da afirmação do cirurgião geral que havia perfuração do implante, foi indicada ao paciente a remoção imediatada prótese, no entanto, o paciente recusou ser operado, deixando o hospital. Após dois meses, evoluiu com hiperemia e saída de silicone pela ferida da mama, quando procurou serviço particular para troca da prótese. Podemos concluir que, apesar da alta especificidade dos atuais exames de imagem, as próteses de alta densidade de silicone podem apresentar-se sem alteração aos exames e sua remoção é o tratamento de escolha...


Assuntos
Masculino , Adulto Jovem , Mama/cirurgia , Próteses e Implantes , Silicones , Procedimentos Cirúrgicos Operatórios , Ferimentos por Arma de Fogo , Técnicas e Procedimentos Diagnósticos , Métodos , Pacientes , Ruptura
2.
Rev. bras. queimaduras ; 11(1): 23-25, jan.-mar. 2012. ilus
Artigo em Português | LILACS | ID: lil-752209

RESUMO

Introdução: Estima-se que 2 milhões de pessoas sofram queimaduras a cada ano no Brasil. Segundo dados do Ministério da Saúde, o Sistema Único de Saúde dispende cerca de 55 milhões de reais para o tratamento de pacientes queimados anualmente. Na região de Sorocaba, SP, observamos grande incidência desse tipo de morbidade. O objetivo deste estudo é descrever as características dos pacientes internados por queimaduras segundo faixa etária, sexo, agente etiológico, extensão da queimadura, complicações e mortalidade. Método: Foram analisados registros de 1988 pacientes internados na Unidade de Tratamento de Queimados (UTQ) do Conjunto Hospitalar de Sorocaba (CHS), no período de 1 de janeiro de 2001 a 31 de dezembro de 2008. Resultados: Com base nos dados analisados, verificou-se que 44% tinham mais de 30 anos de idade, 66% dos casos eram do sexo masculino, os agentes etiológicos mais comuns foram fogo (42%) e escaldo (40%), 45% foram classificados como médios queimados e 24% como grandes queimados. As complicações mais frequentes foram infecção (50%), insuficiência respiratória (19%) e insuficiência renal (17%). A taxa de mortalidade foi de 5,3%. Conclusão: Os pacientes admitidos na UTQ/CHS apresentaram características epidemiológicas variáveis, o que implica na necessidade de abordagens preventivas diferenciadas. Visto que a maioria dos acidentes envolvendo queimaduras é evitável, é necessária a intensificação das campanhas socioeducativas.


Introduction: It is estimated there are 2 million burn injured people in Brazil per year. According to Ministry of Health data the Sistema Único de Saúde spends around 55 million reais to sponsor the treatment of burned patients yearly. We deal with a large number of these cases in Sorocaba, SP. The objective of this study is to describe the inpatients characteristics such as: age classification, sex, etiological agent, burn extension, complications and mortality. Methods: 1988 inpatients files have been analyzed from the Unidade de Tratamento de Queimados (UTQ) of Conjunto Hospitalar de Sorocaba (CHS) from January/1st/2001 to December/31/2008. Results: 44% of the patients were older than 30, 66% of the cases were males and the most common etiologic agents were fire (42%) and scald (40%). 45% were filed as medium burned and 24% as extensive burned patients. The most common complications were infection (50%), respiratory insufficiency (19%), and kidney insufficiency. The death rate was 5.3%. Conclusion: The CHS/UTQ inpatients presented variable epidemiologic characteristics which imply differential prophylactic actions. Since most burning accidents are avoidable it is recommended that preventing social advertisement should be reinforced.


Assuntos
Humanos , Unidades de Queimados , Queimaduras , Epidemiologia
3.
Rev. bras. cir. plást ; 26(2): 189-193, abr.-jun. 2011. ilus
Artigo em Português | LILACS | ID: lil-599291

RESUMO

Avaliação histológica (do local aplicado e órgãos) após preenchimento com PMMA em ratos. Método: Utilizaram-se 60 ratos Wistar, todos receberam aplicação de 1ml de PMMA (Meta-Crill®) em plano profundo, próximo à região occipital. A eutanásia ocorreu em grupos de 15 ratos no 1º, 3º, 6º e 12º mês após aplicação. Resultados: Identificada presença de infiltrado inflamatório e fibrose no local injetado, além da diminuição da quantidade de PMMA em todas as amostras. Reação de corpo estranho (RCE) tipo granuloma ocorreu em 3,3% das amostras (2 ratos). A análise estatística mostrou-se significante pelo teste de Kruskal-Wallis. Conclusão: O PMMA utilizado apresentou maior RCE e evidente fibrose em amostras tardias, podendo ocorrer RCE tipo granuloma. Embora o PMMA pareça seguro, diversas complicações podem ocorrer. Sua utilização deve ser criteriosa, sabendo que granulomas ocorrem independente da técnica.


Histological evaluation (of the applied place and organs) after PMMA filling in rats. Methods: 60 Wistar rats were used; each received an application of 1 ml of PMMA (Meta-Crill®) in deep frame (near the occipital region). The euthanasia occurred in groups of 15 rats at 1, 3,6 and 12 months after application. Results: Presence of inflammatory infiltrate and fibrosis in the injected site, in addition to the reduced amount of PMMA in all samples. Foreign body reaction (FBR) granuloma type occurred in 3.3% of samples (2 mice). Statistical analysis was shown significant by Kruskal-Wallis. Conclusion: The PMMA used had a higher FBR and evident fibrosis in late samples, occurring FBR granuloma type. Although the PMMA seems safe, several complications can occur. Its use should be judicious, knowing that granulomas occur regard less of the technique.


Assuntos
Animais , Ratos , Eutanásia Animal , Reação a Corpo Estranho , Granuloma , Microesferas , Polimetil Metacrilato , Fibrose , Técnicas Histológicas , Injeções , Métodos , Ratos Wistar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...